您当前的位置:五五电子网电子知识应用领域电梯电梯故障代码---三菱GPS-III详细 正文
电梯故障代码---三菱GPS-III详细

电梯故障代码---三菱GPS-III详细

点击数:7739 次   录入时间:03-04 11:59:12   整理:http://www.55dianzi.com   电梯

MON1=1
MON0=0:
7SEG1=1:INV温度检测;
     =2:E-STOP次
     =3:CC-WDT三次
     =4:SLCWDT三次
     =5:电机过电流
     =6:制动器电阻过载
     =7:接触器故障
     =8:终端减速开关故障
     =9:平层开关故障
     =A:称量装置故障
     =B:E1板故障
     =C:UHS/DHS开关故障
     =D:DZ检测回路故障
     =E\F:无
MON0=1:
7SEG1=1:远程复位检测;
     =2:选层器错误16次
     =3:串行故障
     =4:电容器容量不足
     =5:手动运行按钮故障
     =6:速度图形跳转5次
     =7:#LB接触器动作失败5次
     =8:#5接触器动作失败5次 
     =9:#BK1接触器动作失败5次
     =A:#BK2接触器动作失败5次
     =B:LVLT5次
     =C:E1板故障
     =D:风扇故障
     =E\F:风扇或E1板故障
MON0=2:
7SEG1=1:#5  ON故障;
     =2:E-STOP两次
     =3:系统故障
     =4:再复位请求
     =5:PCB基极驱动故障
     =6:DC-CT故障
     =7:无
     =8:浸水感应器故障 
     =9:反浸水动作结束
     =A:#PWD开关指令持续三分钟
     =B:扶手开关保持
     =C:制动器拖动运行结束
     =D:制动器再动作故障
     =E:无
     =F:选层器故障运行16次
MON0=3:
7SEG1=1:MELD过载;
     =2:异常低速
     =3:异常高速
     =4:反转定时
     =5:反向运行
     =6:反转定时器(CWT)
     =7:反转定时器(CWT BS标准)
     =8:逆变器过电压 
     =9:逆变器欠电压
     =A:CC-WDT四次
     =B:SLC-WDT 4次
     =C:逆变器过电流
     =D:SLC E-STOP
     =E:编码器故障(自动)
     =F:编码器故障(手动)
MON0=4:
7SEG1=1:两次E-STOP;
     =2:INV欠电压
     =3:E-STOP F/F复位
     =4:#LB线圈故障
     =5:#5线圈故障
     =6:#BK1线圈故障
     =7:#BK2线圈故障
     =8:上电 
     =9:无
     =A:无
     =B:逆变器充电失败
     =C\D\E\F:无
MON0=5:
7SEG1=1:电气安全回路
     =2:#29锁存
     =3:断电
     =4:INV欠电压
     =5:12V电源故障
     =6:控制屏打开
     =7:手动过载运行
     =8:驱动S/W E-STOP
     =9:管理S/W E-STOP
     =A:无
     =B:异常制动器滑动距离
     =C\D\E\F:无
MON0=6:
7SEG1=1:逆变器欠压;
     =2:PCB基极驱动故障
     =3:INV保护回路动作
     =4:#29锁存
     =5:12V电源故障
     =6:温度开关超75度
     =7:温度开关超90度
     =8


本文关键字:三菱  电梯应用领域 - 电梯