图6 K点发生单相接地故障前后电力系统的运行情况—中性点直接接地运行方式
如果K点的A相发生单相接地故障,则中性点与接地极构成单相接地短路回路,线路上将流过很大的单相短路电流,这是中性点直接接地方式与中性点不接地方式的最根本区别所在。相电压几乎不变,不产生过电压,设备绝缘水平低20%,造价低,节省了投资。因此,综合考虑系统可靠性、绝缘水平和继电保护的要求,中性点直接接地运行方式主要适用于:110kV及以上的电力系统和380/220V的电力系统。
5 结论和展望
本文利用PSCAD/EMTDC软件建立了简单电力系统的中性点运行方式的仿真模型,模拟了在各种运行方式下线路上发生单相接地故障时,电气参数的变化情况,并综合考虑系统可靠性、绝缘水平和继电保护的要求,确定了各种运行方式的适用范围。
参考文献
[1] 杨志洁,平轶玲.浅析电力系统中性点的接地方式[J].山西财经大学学报,2009,31(2):308-308.
[2] 黄晓燕.电网中性点接地方式浅析[J].建筑电气,2009年第8期:15-17.
[3] 阎寒冬,赵义松,于在明.220kV不接地变压器中性点绝缘保护研究[J].东北电力技术,2009年第9期:33-35.
[4] X. B. Zhou, W. B. Wang and J. M. Zhang: Neutral point grounding modes for 10KV grids
in Shanghai shinan area. IET Conference PublICations, 20th International Conference and
Exhibition on EleCTRicity Distribution (Prague 2009)
[5] 张鸿钧,韩敏华.顺义地区中性点接地方式的探讨[J].农村电气化,2009年第9期:40-41.
[6] R. H. Wang: The analysis of specific grounding fault and Petersen on ARC grounding
out arc. Conference Publications, 2010 China International Conference on Electricity
Distribution (Nanjing 2010)
[7] L. J. Kingrey, R. Painter and A. S. LOCker: Applying high resistance neutral
grounding in mediumvoltage systEMS. Industry Applications, IEEE Transactions on.
Vol. 47 (2011), p. 1220
[8] G. K. Jin, A. K, and K. Daewon, M. Park, I. K. Yu, J. Cho, K. D. Sim, S. Kim,
J. K. Lee and Y. J. Won: Development of a PSCAD/EMTDC Model Component for AC Loss
Characteristic Analysis of HTS Power Cable. IEEE Transactions on Applied
Superconductivity. Vol. 20 (2010), p. 1284
[9] M. L. Dong, J. J. He, X. L. Li and Y. Huang: Realization of Self-Defined Control System for Constant Extinction Angle Control Using PSCAD/EMTDC.
Conference Publications, Power and Energy Engineering Conference 2009 (Wuhan, 2009)
[10] H. Ding, M. X. Han, Q. Chen, W. Y. Yin and B. H. Liu: DetaiLED modeling of China-Russia Heihe back-to-back HVDC project using PSCAD/EMTDC. Conference Publications, Electric Utility
Deregulation and Restructuring and Power Technologies, 2008 (Nanjing, 2008)
[11] 石访.电磁暂态软件PSCAD /EMTDC的应用现状与展望[J].华东电力,2008,36(12):36-39.
[12] J. F. Liu, P. L. Wilson and R. P. Jayasinghe: A PSCAD/EMTDC based simulation
study of protective relay. Eighth IEE International Conference on Developments
in Power System Protection, 2004 (Amsterdam, 2004)
作者简介
梁越明(1965-),男,电气工程师,安徽省化工设计院。
钱玉娟(1964-),女,工程师,安徽省淮南市供电公司电力规划设计院。
韩平平(1981-),女,博士,讲师,合肥工业大学。■